Precautions during operation of sealing machine

Mar 06, 2024 Leave a message

1. This machine uses a 220V single-phase three-wire power supply, and the grounding must be reliable, otherwise personal safety will be affected.
2. Metal parts cannot be close to the sensor head.
3. Check the cooling water level frequently. Generally, when using frequently, check once a week and replenish the cooling water. It is best to use non-conductive cooling water.
4. Check the pipes frequently. There should be no leakage or water seepage in the joints. To prevent pipes from freezing due to low temperatures, antifreeze should be injected into the water tank.
5. Maintenance should follow the operating sequence.
6. Maintenance and maintenance should be done by professionals.
7. Do not open the chassis after starting up. The main power supply must be cut off during inspection and maintenance.
8. The machine is designed with an overload and overheating protection system. When the temperature of the heat sink exceeds 70 degrees, the high voltage will be cut off and the warning light will flash: when the load is too large (that is, the diameter of the heated bottle caps is too large or arranged closely or too close to the sensor head), the machine will be instantly overloaded with high voltage current (digital display) Momentarily exceeding "100") can also be protected. This is a normal phenomenon and you can press the "START" key again to start.